Position: Index > Basic Circuit >

Digital Isolation and Termination

2015-01-17 22:02  
Declaration:We aim to transmit more information by carrying articles . We will delete it soon, if we are involved in the problems of article content ,copyright or other problems.
This is a digital isolation and termination circuit. This circuit uses The CLT3-4 that is a digital termination device with quadruple input. The CLT3-4 is designed for 24 V DC automation applications. The CLT3-4 drives an isolating opto-coupler and gives the front-end circuitry of a digital input module (I/O) in industrial automation. Here is the circuit:
digital Isolation and Termination circuit schematic
This circuit has a four channels configuration. It provides a high-density termination by minimizing the external components count. To reduce the printed board size this circuit is housed in a TSSOP20 surface mount package.

This circuit has a serial current limiting circuit, an opto-coupler driver and an input voltage protection. The connection between the logic input and the associated switch or high side sensor is terminated. [Source: STMicroelectronics Application Note]




Reprinted Url Of This Article:
http://freecircuitdiagram.com/2010/04/30/digital-isolation-and-termination/