This digital thermocouple thermometer uses one active component and 15 passive components. With this circuit, both type J and type thermocouples may be used. The type J will measure over the temperature range of 10 to 530?°C with a conformity of ?±2?°C.
Digital thermocouple thermometer

The type will measure over a temperature range of 0?°C to 1000?°C with a conformity of ?±3?°C.