Position: Index > Converter Circuit >

Voltage-to-frequency converter

2016-01-17 00:49  
Declaration:We aim to transmit more information by carrying articles . We will delete it soon, if we are involved in the problems of article content ,copyright or other problems.

The D169 serves as a level detector and provides complementary outputs. The op amp is used to integrate the input signal Vin with a time constant of R1C1. The input (must be negative) causes a positive ramp at the output of the integrator which is summed with a negative zener voltage. When the ramp is positive enough D169 outputs change state and OUT 2 flips from negative to positive
Voltage-to-frequency converter

The output pulse repetition rate ?£>, is directly proportioned to the negative input voltage Vin.