101_V_STANDARD_CELL_REPLACEMENT
National LM199 temperature-stabilized 6.95-V reference is applied to LM3308 opamp through LM321 preamp to give standard-cell replacement that can be adjusted to output of exactly 1.01 V. Null offset of opamp before adjusting for proper output voltage, - Linear Applications, vol. 2, National Semiconductor, Santa Clara, CA, 1976, AN-161, p 5.