Position: Index > Power Supply Circuit >

Regulated Charge Pump

2015-03-21 23:10  
Declaration:We aim to transmit more information by carrying articles . We will delete it soon, if we are involved in the problems of article content ,copyright or other problems.

The dc-dc converter substitutes a voltage tripler in place of the external inductor and the diode that`s typically asRegulated Charge Pump - schematic
sociated with the switching regulator, IC1. Inverting and noninverting amplifiers in the MOS-FET-driver (IC2) activate a diode-capacitor tripling network (D1 through D3, CI through C3). A 50-kHz oscillator residing within IC1 produces the EXT signal (pin 6), IC2 converts this signal into drive signals (180° out of phase) for the tripler. The resulting charge-discharge action in the capacitors recharges C3 toward 10 V every 20 The ferrite bead limits output ripple to about 20-mVpp for a 50-mA load. Conversion efficiency is about 70% for the 5-V input, 10-V output configuration.