This circuit operates by charging a small capacitor from a constant-current source when the pulse to be measured is present. Dual pnp transistor Q3 is the current source; its output current equals the LM329 reference voltage divided by the resistance of potentiometer Rl. When the input is high with no pulse present, Ql keeps the current source turned off. When the pulse begins and the input decreases, Ql turns off and the monostable multivibrator generates a short pulse.
Very-short-pulse-width-measurer

The pulse from the multivibrator turns on Q2, removing any residual charge from the 100-pF capacitor. Q2 then turns off, and the capacitor begins to charge linearly from the current source. When the input pulse ends, the current source turns off, and the voltage on the capacitor is proportional to the pulse width.