A supply monitor using two TL7702A chips monitors the ?± 15-V supplies and activates the back
Backup Supply Activates By Drop-In Main Supply

up supply in case of a voltage drop. Although the chips are intended for use as reset controllers in microprocessor systems, they work well in this application.



Reprinted Url Of This Article: