Sometimes electrolytic capacitors that are stored for some time will exhibit high leakage currents
Electrolytic Capacitor Reforming Circuit

. Before placing these in service, the capacitors might need to be reformed. This power supply can be used for reforming. Adjust R4 for the capacitor`s rated voltage and set S2 in position X. When Ml indicates the rated voltage, reforming is complete. For large capacitors, use position 2, and then position 3 after reforming starts. TX can be any transformer with a rating of 12 to 24 Vac at about 1A.



Reprinted Url Of This Article:
http://www.next.gr/meter-counter/meters/electrolytic-capacitor-reforming-circuit-l14179.html