TRIAC Crowbar For AC Or DC Lines (MBS4991)

2017-07-02 14:55  
Declaration:We aim to transmit more information by carrying articles . We will delete it soon, if we are involved in the problems of article content ,copyright or other problems.

This article describes the TRIAC Crowbar For AC Or DC Lines (MBS4991). The content is very simple, very helpful. Components in this article can help you understand better understanding of this article. For example, in this article, you can go to find and buy these components:MBS4991.

A TRIAC Crowbar circuit which works for both AC and DC voltage is shown in the schematic diagram below. This circuit provide overvoltage protection for electronic or electrical equipment against excessive supply voltage.? Crowbar circuit provide two level of protection. First, this protection circuit will drop the voltage across the protected equipment to near zero by shorting the voltage, and second, the circuit will blow the fuse since it short the current. Here is the schematic diagram of the circuit:

Electronic Crowbar For Ac Or Dc Lines circuit schematic diagram

Using the values for R2, R3 and R1 as shown in the schematic diagram, this circuit can operate within range of 42 to 84 VAC or 60 to 120VDC. R2 set operating point where the crowbar will be triggered. To be safe, the TRIAC voltage rating should be greater than that triggering point, actually it should handle the highest possible voltage exposure. To accommodate testing, when we need to check if the crowbar action is triggered without blowing the fuse, a testing switch? is provided (normally closed push? button). An alarm unit can be added? in parallel with the lamp for audible indication in testing crowbar action.  


Reprinted Url Of This Article:
http://wiringdiagramcircuit.com/triac-crowbar-for-ac-or-dc-lines/